Mindray BC-5150 Hematology Analyzer
BC-5150 Hematology Analyzer
Phone:+86-21-54286005
Resources

Microsystem
Endoscopysystem
Energysystem
BC-5150 Hematology Analyzer
Phone:+86-21-54286005
Auto Hematology Analyzer
Based on Mindray’s continuous innovation in hematology field, BC-5150 is especially tailored to assist diagnostic labs who need full CBC + 5-part results, with relatively low daily sample volume, restricted lab space and tight budget.
As the lightest and most compact 5-part hematology analyzer so far from Mindray, BC-5150 is a highly user-friendly and innovative analyzer that offers cost efficient CBC and 5-part white cell differential results. It is targeted to fulfill and exceed the demands of our global customers by providing more accurate, more efficient and more innovative solutions for labs.
Two kinds of lyse reagents are located inside of BC-5150, which helps the small labs to save space.
The 10.4 inch TFT touch screen with a wide viewing angle, brings convenience to clinicians. Users can complete all instrument operations on the screen, practically eliminating the need for an external PC.
BC-5150 inherits it’s convenient and proven powerful software design from BC-6800 and BC-3600 platforms, the friendly interface is ideal for small sized labs.
Running capillary blood through the sample probe directly is more convenient for the users in children’s hospitals, etc. For Prediluted mode, BC-5150 has higher dilution ratio than other 5-part hematology analyzer, thus it brings a better mixing effect.
Running capillary blood through the sample probe directly is more convenient for the users in children’s hospitals, etc. For Prediluted mode, BC-5150 has higher dilution ratio than other 5-part hematology analyzer, thus it brings a better mixing effect.
There’s NLR parameter in each CBC+DIFF result. Neutrophil-to-lymphocyte ratio (NLR) is calculated by dividing neutrophil count by lymphocyte count, usually from peripheral blood sample. In laboratory medicine, NLR is used as a marker of subclinical inflammation. According to clinical studies, NLR can be used as a prognostic factor of severe illness in COVID-19 patients.
BC-5150 supports bi-directional LIS with test results and patient information. HL7 protocol is supported as well.
Compared with traditional helium neon laser or argon laser,semi-conductor laser has smaller size,lower cost and longer life cycle.
Improved DC impedance technology is used to count and size the RBC and PLT. The smaller counting aperture (50 μm in diameter) provides better performance on samples with low PLT.
Only three routine reagents are required. These have 2 years shelf life and also less consumed by BC-5150. Original QC and calibrator are also provided to ensure the hematology analyzer’s traceability and testing quality.
Principles
Impedance method for RBC and PLT counting
Cyanide free reagent for hemoglobin test
Flow Cytometry (FCM) + Tri-angle laser scatter + Chemical dye
method for WBC 5-part differential analysis and WBC counting
Parameters
25 parameters: WBC, Lym%, Mon%, Neu%, Bas%, Eos%, Lym#,
Mon#, Neu#, Eos#, Bas#, RBC, HGB, HCT, MCV, MCH, MCHC,
RDW-CV, RDW-SD, PLT, MPV, PDW, PCT, P-LCR, P-LCC.
12 research parameters including LIC%, LIC#, ALY%, ALY#,PLT
Clumps#, PLT Clumps%, Lip#, Lip%, NRBC#, NRBC%, Blast#,
Blast%
3 histograms for WBC, RBC and PLT
3 scattergrams for WBC differential
Reagent
M-52D Diluent, M-52DIFF Lyse, M-52LH Lyse, Probe Cleanser
Performance
Parameter |
Linearity Range |
Precision |
Carryover |
WBC |
0-500×109/L |
≤2% (4-15×109/L) |
≤0.5% |
RBC |
0-8×1012/L |
≤1.5% (3.5-6.0×1012/L) |
≤0.5% |
HGB |
0-250g/L |
≤1.5% (110-180g/L) |
≤0.6% |
PLT |
0-5000×109/L |
≤6.0% (100-149×109/L) ≤4.0% (150-500×109/L) |
≤1.0% |
Sample volume
Prediluted mode 20 uL
Whole blood mode 15 uL
Capillary whole blood mode 15 uL
Throughput
60 samples per hour
Display
10.4 inch TFT Touch Screen
Multi-language
Chinese, English, Spanish, Portuguese, Russian, French,
Bahasa Indonesia
Data storage capacity
Up to 25,000 results including numeric and graphical
information
Communication
LAN port supports HL7 protocol
Interface
USB, LAN
Support uni-directional LIS
Printout
External Thermal printer / Laser printer / Inkjet printer, various
printout formats and user-defined formats
Operating environment
Temperature: 10°C~30°C
Humidity: 20%~85%
Air pressure:70 kPa~106 kPa
Power requirement
100V-240V
50Hz/60Hz
Dimension and Weight
Depth(400 mm) x width(320 mm) x height(410 mm)
Weight :24kg