Mindray BC-6800 Auto Hematology Analyzer

BC-6800 Auto Hematology Analyzer

Phone:+86-21-54286005

Resources

BC-6800_Hematology_Analyzer_Brochure

Auto Hematology Analyzer

BC-6800

Exclusive Technology, Inclusive Approach

Today, laboratories not only need more reliable routine CBC plus 5-part diff WBC testing by way of high processing speed, but are also looking for options that extend the analyzer's output in form of Reticulocytes, Nucleated RBCs, Fluorescent Platelet counts etc. for wider clinical application and research. On the other hand, they are restricted by limited budgets. BC-6800 can help to meet all these needs just perfectly and even exceed the expectations.

BC-6800

 

SF Cube Technology

SF Cube is a pathbreaking technology for reliable blood cell analysis, including WBC differential, Reticulocytes and NRBC with efficient flagging. After reaction with proprietory reagents, the targeted blood cells undergo 3D analysis using information from scatter of laser light at two angles and fluorescence signals. The 3D scattergram builds the power to better identify and differentiate blood cell populations, especially to reveal abnormal cell population undetected by other techniques.

SF Cube

 

Additional parameters for further clinical applications

  • IMG(#,%) parameters provide information about immature granulocyte, including promyelocytes, myelocytes and metamyelocytes.
  • HFC*(#,%) parameters represent high fluorescent cell population, such as blasts and atypical lymphocytes.
  • RET(#,%) extend valuable help in the differential diagnosis and/or therapeutic monitoring of anemias.
  • IRF is parameter concerning immature reticulocytes, which can assist in early diagnosis of anemia and monitoring the bone marrow response to therapy.
  • InR*(#,‰) are parameters regarding infected red blood cell. The red blood cells may infected by plasmodium, which can cause malaria.

     * means research parameters

DIFF_scattergram

 

Minimizing interference to ensure more accurate results

  • NRBCs are counted in a dedicated channel by SF cube method, which automatically corrects total WBC count and 5-part Diff results when NRBCs are detected.
  • The Focusing Flow-DC method minimizes the interference traditionally encountered in DC technology to produce near gaussian histograms.
  • PLT-O result avoids the interference from microcytic and fragmented RBCs, large platelets and/or platelet clumps by fluorescent stain, and enhances the results accuracy and sensitivity.

 

High automation to minimize the workload

  • Throughput for 125 tests/hour, autoloader for 100 sample tubes capacity 
  • Bi-directional LIS with HL7 or ASTM communication protocol
  • Customizable re-exam rules allow users to define their re-exam criterion according to lab’s practice

 

Technical Specifications:

Principles
SF Cube* method to count WBC, 5-part diff, NRBC, RET and PLT-O
Focusing Flow-DC method for RBC and PLT
Cyanide free reagent for hemoglobin test
*S: Scatter; F: Fluorescence; Cube: 3D analysis

Parameters

33 reportable parameters: WBC, Lym%, Mon%, Neu%, Bas%, Eos%, Lym#,
Mon#, Neu#, Eos#, Bas#; RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV,
RDW-SD, RET%, RET#, IRF, LFR, MFR, HFR, NRBC#, NRBC%; PLT, MPV, PDW,
PCT, P-LCR, P-LCC
14 research parameters: HFC#, HFC%, IMG#, IMG%, WBC-R, WBC-D, WBC-B,
WBC-N,RBC-O, PLT-O, PLT-I, PDW-SD, InR#, InR‰
2 histograms for RBC and PLT
3 scattergrams (3D) for DIFF, NRBC and RET
6 scattergrams (2D) for DIFF, BASO, NRBC, RET, RET-EXT, PLT-O

 

Performance

Parameter

Linearity Range

Precision

Carryover

WBC

0-500×109/L

≤2.5% (≥4×109/L)

≤1.0%

RBC

0-8×1012/L

≤1.5% (≥3.5×1012/L)

≤1.0%

HGB

0-250g/L

≤1.0% (110-180g/L)

≤1.0%

HCT

0-75%

≤1.5% (30%-50%)

≤1.0%

PLT

0-5000×109/L

≤4.0% (≥100×109/L)

≤1.0%

RET#

0-0.8×1012/L

≤15% (RBC≥3×1012/L;

1%_RET%_4%)

/

 

Sample volume
Predilute mode (capillary blood), Open vial 40uL
Manual mode (whole blood), Open vial 150uL

Autoloader mode (whole blood), Closed vial 200uL

 

Throughput
Up to 125 samples per hour (CBC+DIFF)
Up to 90 samples per hour (CBC+DIFF+RET)

 

Mode
CBC, CBC+DIFF, CBC+RET, CBC+NRBC, CBC+DIFF+RET,
CBC+DIFF+NRBC, CBC+DIFF+RET+NRBC, RET

Data storage capacity
Up to 10,0000 results including numeric and graphical information

Operating environment
Temperature: 15℃~32℃
Humidity:30%~85%

 

Printout
Various printout formats and user-defined formats available


Loading capacity
Up to 100 sample tubes