Mindray BC-7500CRP Auto Hematology Analyzer_Tengrant Ltd.
+86-21-54286005 info@tenmed.net Room 602, Building 1, No. 111 Luxiang Road (Greenland Park Plaza), Baoshan District, Shanghai, China
Language: English

Mindray BC-7500CRP Auto Hematology Analyzer

BC-7500 CRP Auto Hematology Analyzer

Phone:+86-21-54286005

Resources

Auto Hematology Analyzer

BC-7500 CRP

Empowering Pediatric Care

 

Capillary blood auto loading, mixing and sampling

Standardized capillary blood processing procedure helps relieve workload and deliver morereliable test result.

 

Capillary blood autoloading

 

Capillary blood automixing

 

Capillary blood autosampling

 

Highly efficiency solution for pediatric sample analysis

  • Auto loading and sampling improves testing efficiency for pediatric sample
  • Puncturable capillary blood tube
  • Only 27.5 μl blood required for CD mode and 37.5 μl for CD+CRP mode
  • Minimum sample volume: 100 μl

 

Standardized biotic auto-mixing

Auto loading and sampling improves testing efficiency for pediatric sample

Before                                                                                                               After

  

 

High speed CBC+CRP integrated analyzer

  • Simultaneously provides results of WBC differentiation and FR-CRP at a throughput of 100 samples/hour.

  • In children’s hospital, CRP is often required to help differentiate bacterial infections from viral infections.
  • Latex Particle-Enhanced Immunonephelometry Method plus two reagents can ensure the reliability of CRP result.
  • High speed CBC+CRP integrated analyzer helps improve laboratory workflow and TAT efficiency.

 

 

3D SF Cube technology

Improves the detection capability of abnormal samples for pediatrics

 

Improves the detection capability of abnormal samples for pediatrics

Reliable differential result for capillary blood

 

 

 NRBC in every CBC test ensures reliable WBC result in pediatric sample

 

Automatic reticulocyte measurement helps diagnose anemia subtypes

 

More reliable differential result

  • 3D SF Cube technology prevents WBC differentiation from being interfered by lipid particles and PLT aggregation, etc.
  • More reliable WBC result

NRBC in every CBC test avoids falsely-high WBC result

  • Low value WBC is automatically counted in three times to ensure more reliable differential result
  • More reliable PLT result

Automatic PLT-O 8-fold counting makes low value PLT more reliable

  • Patented PLT de-aggregation technology
  • Fluorescent PLT-O avoids large PLT and fragmented RBC interference