Mindray BC-6000 Hematology Analyzer

BC-6000 Hematology Analyzer

Phone:+86-21-54286005

Resources

BC-6000_Hematology_Analyzer_Brochure

Hematology Analyzer

BC-6000

High Performance for ALL

At Mindray, we seek to understand the needs of every customer, and deliver tailor-made solutions. In today's laboratories, lab managers are looking for an analyzer with greater clinical values, such as higher flagging efficiency to reduce the ratio of microscopic examination, NRBC/body fluid results generated in a small-footprint system, among others, all within limited budget. Mindray BC-6000 fulfills all these clinical requirements and exceeds your expectations!

BC-6000

 

SF Cube Technology

With the newly designed opticals and reagent systems, the SF Cube technology can help doctors to better differentiate the clusters of cells (6 parts, including  Immature Granulocyte), which is the key to revealing more abnormal cells.

 

NRBC result in every CBC

In WNB scattergram, BC-6000 provides NRBC, Basophils and WBC-N* results. It means that the actual number of NRBCs can be measured in routine CBC, if they are present in the sample.

Basophils are counted in this counting channel with NRBC results.

Basophil and NRBC results are generated on BC-6000 without extra reagent or cost.

 

NLR parameter in each CBC+DIFF

Neutrophil-to-lymphocyte ratio (NLR) is calculated by dividing neutrophil count by lymphocyte count, usually from peripheral blood sample.

In laboratory medicine, NLR is used as a marker of subclinical inflammation.

According to clinical studies, NLR can be used as a prognostic factor of severe illness in COVID-19 patients. 

 

Automatic Rerun & Reflex

Should the sample results trigger the criteria, the sample rack can automatically step back for a “rerun” or “reflex” check.

 

Less testing time

BC-6000 can load up to 50 samples at a time and offers a throughput of up to 110 tests per hour.

 

Low sample volume

BC-6000 requires less sample volume as well as reagent consumption. For a CBC+DIFF test with NRBC result, BC-6000 only requires 80μL of whole blood and 35 μL of capillary blood.

Principles

SF Cube* method to count WBC, 6-Part diff and NRBC
DC impedance method for RBC and PLT
Cyanide free reagent for hemoglobin test
*S: Scatter; F: Fluorescence; Cube: 3D analysis

 

Parameters

29 Reportable parameters (whole blood): WBC, Lym%, Mon%,
Neu%, Bas%, Eos%, IMG%, Lym#, Mon#, Neu#, Eos#, Bas#, IMG#;
RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, NRBC#,
NRBC%; PLT, MPV, PDW, PCT, P-LCR, P-LCC
20 Research parameters (whole blood): HFC#, HFC%, WBC-D,
TNC-D, IME%, IME#, H-NR%, L-NR%, NLR, PLR, WBC-N, TNC-N,
InR#, InR‰, Micro#, Micro%, Macro#, Macro%, PDW-SD, PLT-I
7 Reportable parameters (body fluid): WBC-BF, TC-BF#, MN#,
MN%, PMN#, PMN%, RBC-BF
11 Research parameters (body fluid): Eos-BF#, Eos-BF%,
Neu-BF#, Neu-BF%, HF-BF#, HF-BF%, RBC-BF, LY-BF#, LY-BF%,
MO-BF#, MO-BF%
2 Histograms for RBC and PLT
2 Three-dimension scatter grams: DIFF, WNB
2 Two-dimension scatter grams: DIFF, WNB

 

Performance

Parameter

Linearity Range

Precision

Carryover

WBC

0-500×109/L

≤2.5% (≥4×109/L)

≤1.0%

RBC

0-8.6×1012/L

≤1.5% (≥3.5×1012/L)

≤1.0%

HGB

0-260g/L

≤1.0% (110-180g/L)

≤1.0%

HCT

0-75%

≤1.5% (30%-50%)

≤1.0%

PLT

0-5000×109/L

≤4.0% (≥100×109/L)

≤1.0%

 

Sample volume

Whole blood (Autoloader, Closed Tube) 80uL
Capillary blood (Closed Tube) 35uL
Predilute (Closed Tube) 20uL
Body fluid (Closed Tube) 85uL

 

Throughput

Up to 110 samples per hour (CBC+DIFF)
Up to 40 samples per hour (Body fluid)

 

Mode
CBC, CBC+DIFF

Data storage capacity
Up to 10,0000 results including numeric and graphical information

Operating environment
Temperature: 15℃~32℃
Humidity:30%~85%


Loading capacity
Up to 50 sample tubes