| Pump function | suction or irrigation pump |
| Unit type | roller pump |
| Power supply | 100 – 240 VAC |
| Width | 305 mm |
| Height | 110 mm |
| Depth | 260 mm |
| Weight | 4.7 kg |
| Line frequency | 50/60 Hz |
| Pressure regulated - Normal | 20 – 150 mmHg |
| Suction flow: Software license IBS shaver | 100 – 300 ml/min |
| Suction flow: Software license URO (RES) | 100 – 1000 ml/min |
| Suction flow: Software license URO (Calcuson) | 300 – 1000 ml/min |
| Suction flow: Software license Hys | 10…180 ml/min |
| Suction flow: Software license Art | 100…1000 ml/min |
| Certified to | IEC 60601-1 |
| Irrigation pressure in flow-controlled procedures | max. 500 mmHg |
| Irrigation flow in flow-controlled procedures | software license SURG (LAP, THOR and PRO): 100-3500 ml/min, software license GI (GASTROENTEROLOGY): 100-1000 ml/min, software license HNO / NEURO: 50/65/80/95/110/130 ml/min |
| Irrigation pressure in pressure-controlled procedures | 20-150 mmHg |
| Irrigation flow in pressure-controlled procedures | software license HYS and URO: max. 600 ml/min, software license SPINE: max. 600 ml/min, software license ART: max. 2500 ml/min |
| irrigation flow (ml/min) | Accuracy (0…3500 ml/min): +-20 %; HYS, URO, SPINE: 200-400-600; ART: 1500-2000-2500; SURG: 100…2500 (Advanced: 100…3500); GI: 100...1000; ENT/NEURO: 50-65-80-95-110-130 |
| max. irrigation pressure (mmHg) | Accuracy (up to 100 mmHg): +-10; HYS, URO, ART, SPINE: 20…150; LAP, GI: 100-300-500 (Advanced only) |
| Brand | ENDOMAT® SELECT |
| Unit communication SCB | yes |
| SCB connection | 2 |
| IP protection class | IP21 |
| Electrical protection class | protection class 1 |
| Degree of safety | CF |
| Control via touch screen | yes |
| Wipe disinfection | yes |
| System requirements for SCB | SCB control NEO system with installed SCB control NEO Software Release 20090001-46 or higher |
| Display | TFT screen |
| Socket for external systems | 1 |
| Unit communication KS HIVE | no |
| Connection socket footswitch | 1 |
| Bottle stand included | no |
| Power consumption | 72 VA |
| Operative procedure | ART, CYST, PCN, URS, RES, HYS, IBS, LAP, PRO, THOR, SPINE |
| Suction flow (ml/min) | IBS shaver: 100...300 ml/min |