The EG-840T therapeutic gastroscopes feature a highsensitivity CMOS sensor and provide a unique 160 degrees down-angulation to also access difficult-to-reach areas.
The instrument channel diameter of 3.2 mm provides a good balance of suction performance and control of the inserted instrument, making it possibly suitable for advanced therapeutic interventions like ESD.
Streamlined design concept for insertion tubes
Since conventional generations, Fujifilm's "gradual stiffness" technology has been incorporated into their colonoscopes in which the stiffness changes over the length of the endoscope being softest at the distal end and hardest at the proximal end. This technology now expands towards the 800 series gastroscopes,aiming to improve insertion and operability in the upper gastrointestinal tract.
These features are expected to improve endoscopic operability, not only for colonoscope insertion, but also in the upper gastrointestinal tract, such as during duodenal insertion.
High-resolution CMOS sensor
Compared to the conventional 760 series endoscopes, the highsensitivity sensors integrated in the 800 series endoscopes enable theimage to be viewed with less noise.
G7 grip for comfort in daily practice
The G7 grip is designed to have an easy and comfortable feel to enhance performance and reduce stress during clinical procedures. Each 800 series endoscope displays the information required to choose compatible accessories, which helps to facilitate on-the-spot decision making.
Labels attached to the control portion, which show 1 Colour code of G7 control portion
the model number and instrument channel inlet size 2 Identification colour of Instrument channel size
3 Instrument channel diameter
4 Corporate brand logo
5 Model number
One-step connector for easy plug-in
One-step connector to incorporate an integrated wireless power supply that provides high-speed transmission of data. The design helps to simplify the cleaning process and reduces the potential for accidental damage.
Close observation at 2 mm
The 2 mm close-up observation is expected to improve visibility during treatment.
White Light Imaging mode BLI Imaging Mode
160° down angulation
The down-angulation of EG-840T and EG-840TP has been increased to 160° from 90° while maintaining an upwards-angulation of 210° which can be found in all 700 series gastroscopes. It is expected to facilitate the observation and treatment of lesions and sites that have been difficult to approach in the past.
Duodenum
EG-760R EG-840T
Stomach
EG-760R EG-840T
Viewing direction |
0°(Forward) |
Field of view |
140° |
Observation range |
2-100 mm |
Distal end diameter |
9.8 mm |
Insertion tube diameter |
9.8 mm |
Minimum diameter of instrument channel |
3.2 mm |
Bending capability |
UP 210° / DOWN 160° |
Working length |
1,100 mm |
Total length |
1,400 mm |