+86-21-54286005 info@tenmed.net Room 602, Building 1, No. 111 Luxiang Road (Greenland Park Plaza), Baoshan District, Shanghai, China
Language: English

ETHICON ER60G 3D Reload, 60 mm, Green

ETHICON ER60G 3D Reload, 60 mm, Green

Phone:+86-21-54286005

Resources

ETHICON 3D 60mm Reloads

Product Codes: ER60G

 

Features & Benefits

3D stapling technology

More evenly distributed pressure designed to reduce leaks and bleeds at the staple line2A

 

References

A. Finite element analysis found a 37% increase in staple line area for ETHICON™ 3D Reloads compared to ECHELON ENDOPATH™ Reloads with GST. Evaluation of leakage pathways. ETHICON™ 3D Reload (ER60B) had less leak pathway area at 0.302 in2 compared to ECHELON ENDOPATH™ GST Reload (GST60B) at 0.401 in2. 

B. Consistency is defined as reduced staple height variation along the staple line. This is measured by the range of average delta from nominal staple height within the functional zone (in mm): ETHICON™ 3D Reloads (0.0128 - 0.0242); Tri-Staple™ Reloads (0.0403 - 0.0720). 

C. The tissue range of ETHICON™ 3D Reloads is expanded compared to the ECHELON ENDOPATH™ GST Reloads. 

D. Evaluation of leakage pathways. ETHICON™ 3D Reload (ER60B) had less leak pathway area at 0.302 in2 compared to ECHELON ENDOPATH™ GST Reload (GST60B) at 0.401 in2. 

E. Evaluation of leakage resistance: ETHICON™ 3D Reload (ER60B) had less leak pathway area at 0.302 in2 than ECHELON ENDOPATH™ GST Reload (GST60B) at 0.401 in2. Intervention comparison based on retrospective comparative analysis of hemostasis performance in a porcine model for the ETHICON™ 4000 Stapler with 3D Reloads (EC3D60C & ER60W) vs. the ECHELON™ 3000 with GST Reloads (ECH60C & GST60W), n=114. 

F. Exceptional staple line integrity based on staple form quality assessment for ETHICON™ 3D Reloads (ER60W/B/G/T). Tissue thickness range comparison: ETHICON™ 3D reloads (maximum 4.0mm) versus Tri-Staple™ reloads (maximum 3.0mm). 

  1. Johnson & Johnson and its affiliates. Ethicon™ 4000 with Ethicon™ 3D Reloads – Staple Performance Claims. February 2024. Windchill # 502188145
  2. Johnson & Johnson and its affiliates. Evaluation of Leak Pathways for Claims: Echelon 4000 with 3D Reloads vs Echelon 3000 Stapler with GST. November 2024. Windchill # 502123426
  3. Global Business Insights. JJMT Market & Share 4Q'24 WW Surgery. March, 2025 
  4. Johnson & Johnson and its affiliates. Project Royal Thick Tissue Investigation. July 2024. Windchill # 502031130 
  5. Johnson & Johnson and its affiliates. Project Royal Retrospective Analysis: Hemostasis Performance Evaluation of Royal Stapler with Royal 3D 60 mm White Reload Compared to the ECHELON™ 3000 Stapler with 2D Gripping Surface Technology 60 mm White Reload in Non-Survival Swine Gastroepiploic Models. January 2025. Windchill #PRE 24-0058 
  6. Medtronic Tri-Staple™ Reload. Intended Tissue Thickness Range. Document #P100153.