ETHICON GLC60 ECHELON LINEAR™ 60mm Cutter

ETHICON GLC60 ECHELON LINEAR™ 60mm Cutter

Phone:+86-21-54286005

Resources

ECHELON LINEAR Cutter

Product Codes: GLC60

The ECHELON LINEAR™ Cutter is the first linear cutter with locked halves that allows for one-handed device placement.A,1,2 It had 47% fewer leakage pathways at the staple line compared to ETHICON™ Linear Cutter and GIA™ with Tri-Staple™ Technology; and 67% fewer leakage pathways at the staple line compared to GIA™ with DST™ Technology.B,3 

 

Features & Benefits

More Evenly Distributed Compression

The ECHELON LINEAR™ Cutter with 3D stapling technology provided more evenly distributed compression throughout the staple line compared to Medtronic GIA™ with DST™ Technology.C,5

 

Lower Potential of Tissue Slippage

The ECHELON LINEAR™ Cutter is designed to stabilize and compress the tissue where it is needed, which may result in lower potential of tissue slippage versus traditional linear cutters.D,6,7 

 

One-Handed Device Placement

The ECHELON LINEAR™ Cutter is the first linear cutter with locked halves that allows for one-handed device placement on tissue.A1,2

 

References

A. Based upon surgeon usability evaluation, 32 out of 37 responses were in a favorable view of ECHELON LINEAR™ Cutter enabling one-handed positioning and placement when the halves are locked.

B. Benchtop testing on porcine colon measuring leakage pathway rates at the staple line at 30mmHg, comparing rates of 52.8% for ETHICON™ Linear Cutter [NTLC] (NTLC75 with SR75 at lower (blue) tissue gap setting), 52.8% for Medtronic GIA with Tri-Staple (GIA80MTS with purple medium/thick reloads GIA80MTC), 83.3% for Medtronic GIA with DST (GIA8038S with blue reload GIA8038L), to 27.7% for Echelon Linear Cutter (GLC80 with blue reload GLCR80B) (n=36, p<0.001). Based on benchtop testing and clinical effect is unknown.

C. Staple line compression analysis on Ethylene-Vinyl Acetate (EVA) foam assessing the deformation of foam. ECHELON LINEAR™ Cutter (GLC80 with GLCR80B) had better distributed compression pressure at 7.20% average pressure variation (N=30,320) compared to Medtronic GIA™ with DST™ Technology (GIA8038S with GIA8038L) at 10.93% (N=31980), (p=.001). Based on benchtop testing and clinical effect is unknown.

D. Benchtop testing in 1.5mm porcine colon measuring tissue slippage failure rate under high cutting force. ECHELON LINEAR™ Cutter with Gripping Surface Technology (GLC80 with GLCR80B) [3.75%] compared to ETHICON™ Linear Cutter (NTLC75 with SLR75 at blue tissue gap setting) [15.64%] and Medtronic GIA™ with DST™ Technology (GIA8038S with GIA8038L) [18.83%], n=12. Based on benchtop testing and clinical effect is unknown.

  1. Ethicon, Echelon Linear Cutter (Cornerstone) Customer Usability Claim Summary Report, A.3. 11/10/2022. Windchill Document #501027381. (EM_ETH_STAP_304882.1)
  2. Ethicon, Cornerstone Design Plan, T.2. 04/09/2024. Windchill Document #DC002975. (EM_ETH_STAP_304882.1)
  3. Ethicon Cornerstone Staple Line Leak Claims Testing, A.9. 01/19/2023. Windchill Document #500897557. (EM_ETH_STAP_303485)
  4. ECHELON™ Linear Cutter Instructions for Use. Ethicon, Inc.
  5. Ethicon Cornerstone More Evenly Distributed Pressure Claim Completion Report, B.5. 09/27/2023. Windchill Document #500916693. (EM_ETH_STAP_385415)
  6. Ethicon, Cornerstone Less Compression Forces on Tissue (Gentler Handing) Claim Completion Report. 12.15.2022. Windchill Document #500964180. (EM_ETH_STAP_385809)
  7. Ethicon, Echelon Linear Cutter (cornerstone) Tissue Grasping force and Knife Cutting Force Measurement, A.6. 12/15/2022. Windchill Document #501006140. (EM_ETH_STAP_385809)