CANON 320 rows CT Aquilion ONE INSIGHT Edition
Aquilion ONE INSIGHT Edition TSX-308A
Phone:+86-21-54286005
Resources

Microsystem
Endoscopysystem
Energysystem
Aquilion ONE INSIGHT Edition TSX-308A
Phone:+86-21-54286005
The Aquilion ONE / INSIGHT Edition is built with our next-generation gantry and optics, offering the latest Deep Learning Reconstruction technology, PIQE 10241.
Offering a streamlined system design and intuitive workflow experience with INSTINX automated workflow, enabling quick, consistent and efficient CT exams while keeping your patients' needs a priority.
1 PIQE is designed to fully utilize the maximum resolution of the detector.
2 Option
3 Depending on system configuration.
4 Based on an ALD evaluation of 240 3D Landmark scans (40 Head, 200 Body) 3D landmark scan data. Cases in which the relevant anatomic landmark(s) were not present (9) were excluded. 97% accuracy is based on results within +/- 1cm of target start, end, and FOV position, confirmed by two experienced CT Technologists.
1 Option
2 Depending on system configuration.
3 PIQE is designed to fully utilized the maximum resolution of the detector.
Optimizing workflow with INSTINX1, AI-assisted workflow automation that sets new standards in efficiency and consistency.
1 Depending on system configuration.
Empowering you to work smarter and faster with greater confidence and consistency.
1 PIQE is designed to fully utilize the maximum resolution of the detector.
Intuitive, integrated, and advanced technologies on the Aquilion ONE / INSIGHT Edition with next-generation gantry and optics.
1 Depending on system and configuration.
2 PIQE is designed to fully utilize the maximum resolution of the detector.
Ultra-fast acquisitions with the synergy of the PUREINSIGHT detector with wide-area 16 cm coverage, ultra-fast 0.24 sec rotation*, powerful 100 kW generator* and CoolNovus X-Ray tube.
* Option
1 Compared to conventional CT scanners.
2 Low 70 kV is dependent on patient size and type of study.
Let the Aquilion ONE / INSIGHT Edition do the heavy lifting with innovative technology to improve patient access, comfort, and safety.
* Option
1 Depending on system configuration.
2 Optimal dose and image quality occur at isocenter.
* Depending on system configuration.
1 Based on a study performed at Hakujyuji Hospital, Japan with 40 cases, 10 technologists comparing manual scan planning on Aquilion ONE with automatic scan planning on Serve for body examinations.
2 Based on an ALD evaluation of 240 3D Landmark scans (40 Head, 200 Body) 3D landmark scan data. Cases in which the relevant anatomic landmark(s) were not present (9) were excluded. 97% accuracy is based on results within +/- 1 cm of target start, end, and FOV position, confirmed by two experienced CT Technologists.
* Depending on system configuration.
1 Based on a study performed at Hakujyuji Hospital, Japan with 40 cases, 10 technologists comparing manual scan planning on Aquilion ONE with automatic scan planning on Serve for body examinations.
2 Based on an ALD evaluation of 240 3D Landmark scans (40 Head, 200 Body) 3D landmark scan data. Cases in which the relevant anatomic landmark(s) were not present (9) were excluded. 97% accuracy is based on results within +/- 1 cm of target start, end, and FOV position, confirmed by two experienced CT Technologists.
3 SURESubtraction Iodine Mapping and Bone Removal.
The beam shaping energy filter leverages the photon-attenuating properties of silver to selectively remove low-energy photons from a polychromatic X-ray beam, leaving an optimized energy spectrum.
* Not all options/features may be available across all systems/configurations
1 Depending on system configuration.
2 Courtesy of Dr. M Chen, NHLBI, National Institutes of Health, USA
3 Courtesy of Dr. Bull, Bournemouth, UK
PIQE 10241 DLR maximizes the inherent resolution of a CT to provide Super Resolution1 images without comprising on image noise, temporal resolution or dose.
PIQE 1024* Cardiac delivers sharper images for better visualization of stents, calcification and plaque.
PIQE 1024* Body provides images with less noise and sharp borders between lesions seen in the liver or kidneys.
PIQE 1024* Lung2 provides sharp anatomical detail for improved visualization of the lung parenchyma, without dose penalties.
* Option
1 PIQE is designed to fully utilize the maximum resolution of the detector.
2 PIQE Lung based upon NEQ measurements, e.g. increase in NEQ by a factor of X (range y – z) for frequencies above 0.5 lp/mm for a 320 mm FOV at an SSDE of 9mGy.
These results are based upon the customer’s specific experience. Clinical results are the experience of the author. Results may vary due to clinical setting, patient presentation and other factors.
Deep Learning Reconstruction (AiCE delivers our best low-contrast resolution ever1, with improved low-contrast detectability, noise and spatial resolution relative to hybrid iterative reconstruction.
11.5 mm @ 0.3%, Aquilion ONE / GENESIS Edition
Wide-area CT comprehensive stroke evaluation with whole brain1 perfusion with 4D digital subtraction* angiography of the intracranial circulation in just one minute.
Evaluate flow and perfusion defects with 4D brain perfusion2 Vitrea software to make the appropriate treatment decision in under five minutes.
Technology Highlights:
* Option
1 Available on the Aquilion ONE / INSIGHT Edition, Aquilion ONE / Prism Edition, Aquilion ONE / Genesis Edition.
2 Available with Vitrea Advanced Visualization.
Images Courtesy of Radboud UMC, Nijmegen, The Netherlands.
* Option
1 Gray scale iodine maps directly from CT console, color iodine maps only with Advanced Vitrea application.
2 In combination with Vitrea® Advanced Visualization.
Main specifications
Detector |
PUREINSIGHT detector |
|
320 rows, 0.5 mm,16 cm z-axis coverage |
||
X-ray Tube & generator |
kV 70-135, Maximum mA 1400 |
|
Gantry |
Rotation time |
0.24 s*1, 0.35 s |
Bore size |
80 cm |
|
Bore depth |
36.3 cm |
|
Physical Tilt |
±30° |
|
Patient couch |
Speed |
450 mm/s |
Load |
315 kg*2 |
|
Max. scan range |
150-200 cm*2 |
|
Reconstruction speed |
|
Max. 80 fps |
Reconstruction |
Iterative reconstruction |
AIDR*3 3D Enhanced |
Deep Learning Reconstruction |
PIQE*1, AiCE*1 |
|
Installation |
Power capacity |
140 kVA*1, 100 kVA |
Space |
19.38m2 *1 |
*1 Requires option license
*2 Option, with 1200 mm stroke
*3 Adaptive Iterative Dose Reduction