FUJIFILM ELUXEO EP-8000 Processor & Light Source
FUJIFILM ELUXEO EP-8000 Processor & Light Source
Phone:+86-21-54286005
Microsystem
Endoscopysystem
Energysystem
FUJIFILM ELUXEO EP-8000 Processor & Light Source
Phone:+86-21-54286005
Advanced image quality
Image processing has been redesigned and now supports 4K resolution output. With Triple Noise Reduction and Extended Dynamic Range Technology, the images become sharper and brighter than ever before. All endoscopes of the 800 series are equipped with a CMOS sensor.
TRIPLE NOISE EXTENDED CMOS TECHNOLOGY
REDUCTION DYNAMIC RANGE
Expanded therapeutic solution
The EP-8000 processor offers the new ACI (Amber-red Color Imaging) observation mode, designed to enhance the visualisation of slight colour tone differences of blood colour (e.g. for the estimating of the bleeding source). Furthermore, the portfolio has been extended by two gastroscopes dedicated to advanced treatment.
MULTI LIGHT ACI 160° DOWN
TECHNOLOGY BENDING CAPABILITY
Efficient workflow
Designed for ease-of-use and dynamic workflow management, the EP-8000 offers improved connectivity that can be expanded with various peripheral devices and systems.
BRIGHTER & SHARPER IMAGES WITH LESS HALATION
Triple Noise Reduction
Fujifilm's latest Triple Noise Reduction (3NR) combines proprietary noise reduction technologies from three core imaging modalities including; X-ray, Ultrasound and conventional Endoscopy.
Image processing and noise reduction3 modalities to reduce noise
1. from X-ray:
By analysing line structures such as blood vessels
2. from Endoscopy:
By analysing sequential frames
3. from Ultrasound:
By analysing surface structures such as mucous membranes
Extended Dynamic Range
Fujifilm's dimming and tone control technology 'Extended Dynamic Range' dynamically adjusts the brightness of the near and far field, reducing halation in the near field. This results in an overall brighter and more detailed video image.
* Dynamic Range is the range of tonal difference between the lightest light and darkest dark of an image
Multi Light Technology
Achieving improved diagnostic and therapeutic results in endoscopic procedures is highly dependent on image quality. As one of the world's largest imaging companies, our long-standing experience in medical imaging has allowed Fujifilm's engineers to develop Multi Light technology, fulfilling the need for improved visualisation in endoscopy – today and in the future.
This illumination creates high-quality images with White Light Imaging and the observation modes LCI, BLI and ACI. With a simple push of a button, you can easily switch between the observation modes.
Example of ESD workflow & usage of each observation mode
ELUXEO® 8000 endoscopy system provides detailed high-resolution imaging for both diagnosis and pre-therapeutic assessment as well as therapeutic interventions.
White Light Imaging
The endoscopic system provides high image quality in terms of sharpness and brightness to gather necessary visual information for diagnostic and therapeutic procedures in daily clinical practice.
LCI (Linked Color Imaging) mode
LCI differentiates the red colour spectrum more effectively than White Light Imaging thanks to its preprocess composition of light spectrum and Fujifilm's original signal processing. The increased colour contrast in red colour leads to improved visibility of abnormalities, inflammation and delineation.
BLI (Blue Light Imaging) mode
High-intensity contrast imaging with BLI is expected to be helpful for improved visualisation of superficial vascular and mucosal patterns. Focusing on the characteristics of short wavelength absorption of haemoglobin (at 410 nm) combined with specific white light spectral colours results in improved contrast imaging.
ACI (Amber-red Color Imaging) mode
ACI is an observation mode that combines LCI colour enhancement technology with brightness enhancement technology. ACI specifically aims to visualise subtle nuances in red colouration while maintaining a colour tone similar to White Light Imaging,potentially making it a tool for identifying bleeding sources during ESD and other 3rd space endoscopy treatments.
White Light Imaging ACI Mode
Colour enhancement
LCI employs a red colour tone as a reference that is close to the mucous membrane, whereas ACI references red colour tones similar to blood. In both observation modes the contrast of red colour tones is increased in a post-processing step.
Brightness enhancement
ACI emphasises the difference in colour shade by adjusting the brightness. This further enhances the contrast of the red colour tones closest to blood.
Switching observation modes
With a simple push of a button, you can easily switch between the following observation modes.
The order and settings can be changed as desired.
Observation modes compatibility
Endoscope |
BLI |
LCI |
ACI |
FICE |
800 / 700 system endoscopes |
● |
● |
●* |
● |
600 system endoscopes |
|
|
|
● |
580 system endoscopes |
|
|
|
● |
530 system endoscopes** |
|
|
|
● |
* Only 860 series, 840 series, 760 series, 740 series endoscopes
** Only EB-530H, EB-530P, EB-530S, EB-530T, EB-530XT, EB-530US
Efficient Workflow
The EP-8000 has enhanced linkage and expandability with various peripherals and systems. It supports easy operation and efficient workflow management.
GW-100 CO2 Insufflator
The EP-8000 can automatically detect the use of GW-100 CO2 insufflator and deactivate the air insufflation of the EP-8000 to help prevent the over insufflation.
4K Monitor
Now 4K ready, the EP-8000 is installed with a 12G-SDI output, providing the possibility of 4K video quality.
Ultrasound Endoscopy System
Ultrasound endoscopic images can be consolidated and stored on the EP-8000 for centralised management.
Two digital inputs for PoP
The EP-8000 system is equipped with two digital video input terminals, allowing for two PoP video images to be displayed simultaneously on the endoscopy monitor.
Endoscope visualisation system
Fujifilm's Endoscope Visualisation System displays the shape of the endoscope in real-time by reproducing a coloured graphical representation of the endoscope next to endoscopic view.
Endoscopy support
CAD EYE aims to support the detection and characterisation of colorectal polyps. It works with all ELUXEO® 800 & 700 series colonoscopes combined with EW10-EC02 software and EX-1 hardware.
SCALE EYE is designed to assist endoscopists in estimating the size of an object (e.g. polyp)in the colon.
JW-3 Water Pump
The EP-8000 can now be configured to enable water jet activation at the press of the endoscope switch when used in combination with the JW-3 water pump.
Endoscopes compatibility
The EP-8000 is compatible with a wide variety of Fujifilm endoscopes ranging from 530*/580/600 system xenon light based endoscopes to the more advanced 700 and 800 system ELUXEO® generation endoscopes.
*Only EB-530H, EB-530P, EB-530S, EB-530T, EB-530XT, EB-530US
Power Supply |
100-240V ~50/60 Hz |
Current Consumption (Rated) |
3.0-1.5A |
Fuse |
T5AH250V x 2 (Rated: 5A/250V) |
Color Format |
NTSC/PAL |
Video Output |
DVI (Resolution: 1920 x 1080 pixels) |
Dimming |
Automatic dimming via control signal |
Air Pump |
Strong / Medium / Weak / Off |
Maximum Supply Pressure |
65kPa |
Maximum Water Pressure |
65kPa |
Water Supply Method |
Pressurizes the water tank with air and delivers water |
Light Source |
LED |
Maximum Light Output |
3.6W or less (based on our measurement tool) |
Power Transmission Frequency |
110-205KHz |
Effective Radiated Power |
Less than 15W |
Image Format |
Simultaneous Method*1 |
Photometry Method |
Auto/Peak/Average |
Screen Magnification*2 |
Electronic Zoom: ×1.00 to ×2.00 (0.05 steps) |
Memory |
Patient Data: 45 patients |
Built-in Clock |
Date, Clock |
Counter |
Forward counting display |
Applicable Endoscopes*3 |
800 System Scope*4 |
Dimensions (W x H x D) |
395 x 210 x 515 mm (including protrusions) |
Weight |
18 kg |
*1 This imaging method uses an imaging sensor with different color filters (red, green, and blue) mounted on the tip of the endoscope, illuminated by white light.
*2 The magnification range for some 530 series endoscopes is 1.00x to 1.95x.
*3 Image enhancement functions available for each endoscope are as follows:
800/700 system endoscopes (excluding 710/720 series endoscopes):
FICE, BLI, BLI-bright, LCI, ACI
710/720 series endoscopes, L600 system endoscopes, L580 series endoscopes, EB580S:
FICE, BLI, BLI-bright, LCI
600 system endoscopes, 580/530 series endoscopes:
FICE
*4 Except EG-840UR
*5 Except EC-760S-A/M and EC-760S-A/L
*6 EB-530H, EB-530P, EB-530T, and EB-530US only