Medtronic 1894510 XPS Nexus Console
Medtronic 1894510 XPS Nexus Console
Phone:+86-21-54286005
Microsystem
Endoscopysystem
Energysystem
+86-21-54286005
info@tenmed.net
Room 602, Building 1, No. 111 Luxiang Road (Greenland Park Plaza), Baoshan District, Shanghai, China
Medtronic 1894510 XPS Nexus Console
Phone:+86-21-54286005
TAKING SINUS SURGERY FURTHER, TOGETHER

Connects the M2, M4,and Indigo™
Handpiece recognition
Portable, easy to transport,and lightweight
IV pole (sold separately)
Built-in irrigation pump
Intuitive design with a user-friendly interface
Quick and simple set up
Foot pedal with non-slip design (sold separately)


A Pump Panel
1. Flow selection (CC/min)
2. Flow increase
B M2/M4 Panel
3. Oscillation mode
4. RPM selection
5. Forward mode
6. RPM increase/decrease
C Indigo Panel
7. Forward
8. Reverse
9. RPM selection
10. RPM increase/decrease
D Irrigation Pump
E Power/Connection Panel
11. Indigo, M4/M2 receptacle
12. Power light (green)
13. Error indication light (amber)
14. Handpiece alignment mark
15. Foot pedal receptacle
Description Part Number
XPS Nexus™ Console................................................................................... 1894510
XPS Nexus™ Foot Control........................................................................... 1894520
XPS Nexus™ IV Pole..................................................................................... 1894515
XPS Nexus™ Carrying Case......................................................................... 1894525
|
Physical Dimensions |
Console |
|
|
Size |
265 mm W x 185 mm H x 280 mm D |
|
|
Weight |
4.6 kg |
|
|
Foot control |
|
|
|
Size |
200 mm W x 62 mm H x 220 mm D |
|
|
Weight |
1.5 kg |
|
|
IV Pole |
|
|
|
Size |
315 mm W x 620 mm H x 90 mm D |
|
|
Weight |
0.55 kg |
|
|
Operational Environment |
Temperature |
+10°C to +33°C |
|
Humidity |
30% to 75% RH |
|
|
Barometric Pressure |
700 - 1060 hPa |
|
|
Transport and Storage Environment |
Temperature |
-40°C to +70°C |
|
Humidity |
Up to 95% RH at 35ºC for maximum 3 days |
|
|
Barometric Pressure |
500 to 1060 hPa |
|
|
Electrical |
Input Voltage |
100 -240 V~ ± 10% |
|
Frequency |
50/60 Hz |
|
|
Power Consumption |
180 VA |
|
|
Internal Fuse |
5 x 20 mm, T 4AH, 250 V |
|
|
Duty Cycle for Applied |
Maximum On Time 55 Seconds |
|
|
Part (Magnum II/IV) |
Minimum Off Time 30 Seconds for a 30 min of duty cycle. Minimum 1 hour rest before restarting the duty cycle. |
|
|
Duty Cycle for Applied |
Maximum On Time 3 minutes at 60000 rpm |
|
|
Part (Indigo) |
Minimum Off Time 25 minutes |
|
|
Type of protection against electrical shock |
Class 1 |
|
|
Degree of protection against electrical shock |
Type BF |